E-ABR in Patients with Cochlear Implant: A Comparison between Patients with Malformed Cochlea and Normal Cochlea

2019

Objectives This study aims to compare the electrical auditory brainstem response (EABR) following cochlear implant (CI) surgery in pediatric subjects with cochlear malformation and a normal cochlea, in order to assess the sensitivity of EABR and to evaluate the surgery outcome. Materials and methods A total of 26 pediatric subjects who were deaf and scheduled for CI surgery were enrolled into this case control study. Group A (n=20) included subjects with a normo-conformed cochlea. Group B (n=6) included subjects with cochlear malformation. Subjects were evaluated with EABR immediately (T0) and 6 months (T1) post-CI surgery. The EABR Waves III and V average amplitude and latency were compare…

Malemedicine.medical_specialtymedicine.medical_treatmentOtoacoustic Emissions SpontaneousEABRCochlear nerve conductionDeafnessAudiologyABRPostoperative ComplicationsCochlear malformationCochlear implantEvoked Potentials Auditory Brain StemReaction Timeotorhinolaryngologic diseasesHumansMedicineIn patientCochlear implantCochlear NerveCochleamedicine.diagnostic_testbusiness.industrySignificant differenceInfantMagnetic resonance imagingGeneral MedicineCochlear malformationlcsh:OtorhinolaryngologyMagnetic Resonance Imaginglcsh:RF1-547CochleaSettore MED/32 - AudiologiaCochlear ImplantsSettore MED/31 - OtorinolaringoiatriaAuditory brainstem responseOtorhinolaryngologyCase-Control StudiesChild PreschoolSurgery outcomeFemaleOriginal ArticleABR; Cochlear implant; Cochlear malformation; Cochlear nerve conduction; EABR;Tomography X-Ray Computedbusiness